SPECIFICATIONS | |||
Nominal Capacity Signal output at capacity Linearity error Non-Repeatability Combined Error Hysteresis Creep/Zero Return (30 mins) Zero Balance Temperature Effect on Span/10°C Temperature Effect on Zero/10°C Compensated Temperature Range Operating Temperature Range Service Load Excitation +ve Signal +ve |
100kg ~ 1t 2mV/V ± 0.1% < 0.025% FSO < 0.020% FSO < 0.030% FSO < 0.020% FSO < 0.050% / 0.035% FSO < 3.000% Capacity < 0.015% FSO > 0.020% Capacity -10 ~ 40°C -30 ~ 70°C 100% of Rated Capacity RED GREEN |
Safe Load Ultimate Load Input resistance Output Resistance Insulation Resistance (brd to grd) Excitation Voltage (Rec) Excitation Voltage (Max) Storage Temperature Range Cable Type ... Cable Length Material Finish Excitation -ve Signal -ve |
125% of Rated Capacity 300% of Rated Capacity 410Ω nominal 352Ω nominal > 5000 MΩ at 100V DC 5 ~ 12V AC/DC 15V AC/DC -50 ~ 70°C 4.5mm, Screened, PUR Sheath 4 Core x 0.24mmª (24 AWG) 3 Metres Aluminium Marine Anodised BLACK WHITE |
DIMENSIONS | CAPACITIES | |
Model AST-100kg AST-250kg AST-500kg AST-1t |
Capacity 100kg 250kg 500kg 1t |
Dimensions (mm) | |||||||||
Capacity | A | C | H | T | W | Weight(kg) | |||
100kg | 19 | 12.5 | 70 | M8 x 1.25P | 64 | 0.26 | |||
250kg | 19 | 12.5 | 70 | M8 x 1.25P | 64 | 0.26 | |||
500kg | 25 | 17.5 | 85 | M12 x 1.75P | 70 | 0.40 | |||
1t | 25 | 20 | 96 | M12 x 1.75P | 75 | 0.50 |