Feature
High resolution
High precision (more than 0.01% F.S) and stability
Relay output : Hi, Low, NG, OK.
UNIT CONVERSION : kg, N, ℓb, kg/㎠, bar, MPa
Calibration of actual load and sensor output value
Built-in Shunt calibration switch
Peak & sample hold
Watch dog
OPTION
OP-01 : BCD paralle out
OP-02 : RS232C serial interface
-
OP-03 : RS485 Multi drop interface
Specifications
Accuracy Specification DN100 DN200 Application sensor Strain guage sensors Sensor authorized voltage
(the number of Loadcell connection)DC 5V, Loadcell(350Ω) available 4 Zero adjustment range 00%F·S (Auto Zero) Input signal 0.5~3mV/V Display -19999~+99999 Character height 7Segment 14mm & 10mm Decimal point Random setting available A/D converter 16bit 5000 times/sec 24bit 1000 times/sec D/A converter 16bit 1000 times/sec 16bit 1000 times/sec Relay output Contact capacity : AC250V 5A , Relay life time : more than 5,000,000 times Zero variation Within 0.5μV/℃ Sensitivity variation Within 0.01%/℃ Voltage output DC 0 ~ 10V (4~20mA : in accordance with customer request) Usage temperature range -10℃ ~ 60℃ Humidity Less than 80% RH (no dew condensation) Power source used AC 85 ~ 265V 50/60Hz Option Weight: 1000g OP-01 : BCD output OP-02 : RS232C serial interface OP-03 : RS485 Multi drop interface OP-04 : RS422A serial interface OP-06 : Power 24VDC 제품치수 (unit:mm)